top of page

Modular circuit-breakers up to 63A - C60

Nominal current: 1 to 63A 
Large choice of breaking capacities and tripping curves: B,C,D... 
Compliance with standards: IEC EN 60898 or IEC 60947-2 depending on the version, certified

by national official authorities.
Suitable for isolation in accordance with industrial standards: IEC 60947 
Operating voltage: up to 440 Vac, insulation voltage: 500V 
Optional add-on earth leakage modules: C60 Vigi 
Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip

Residual current circuit breakers

Nominal current:1 to 125 A 
30mA sensitivity:additional protection against direct contact (in accordance with IEC 364) 100, 300, 500 mA sensitivities:additional protection against fire and indirect contact (in accordance with IEC 364) 
B type:protection of installations with three-phase rectifier Type "si": protection of sensitive circuits (computing equipment) and those prone to disturbances (ballast lighting, power electronics) 
Selective version :tripping of the device the closest to the fault 
Compliance with standards:IEC EN 61008 certified by national official authorities 
Suitable for isolation in accordance with industrial standards: IEC 60947 
Operating voltage:up to 440Vac, insulation voltage: 500V 
Optional auxiliaries:indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip

Protection of photovoltaic installations - C60PV DC

C60PV-DC: 
circuit breaker to protect photovoltaic modules against fire in case of short-circuits 
Insulation voltage Ui = 1000 V 
Max. operating voltage Ue = 650 V DC 
Ratings: 10 – 16 – 20 A Non-polarised (two-way) C60NA DC: modular switch electrically insulating

a chain of modules in any enclosure managing more than 3 chains Insulation voltage Ui =1000V 
Max. operating voltage Ue = 650V DC Max. current Ie = 20 A / 650 V to 50 A / 300 V
Non-polarised (two-way) SW60 DC: modular switch electrically insulating the UPS from the upstream generators. 
Insulation voltage Ui =1000 V Max. operating voltage Ue =1000 V DC Max. current Ie = 63 A Polarised (one-way)

Molded Case Circuit Breaker

Nominal current:15 to 630 A 
4 breaking performances from 36 to 150 kA at 415 V 
Voltage rating:up to 690 V 
2 physical sizes from 15 to 630 A 
1, 2, 3 and 4-pole versions 
Isolation with positive break indication 
5 types of electronic and thermal-magnetic protection Earth leakage protection by associated Vigi Module 
Communication networking by associated Measurement Unit Wide range of common auxiliaries

and accessories interchangeable on site 
Compliance with international standards:IEC 60947-1

Circuit-Breakers from 630 to 1600 A - Masterpact

Nominal current:630 to 1600 A 
Breaking performance:42 to 150 kA at 220/415 V AC 
Voltage rating:up to 690 V 
1 single physical size from 630 to 1600 A 
A single pole pitch of 70 mm 
3 and 4-pole versions 
4 Micrologic control units enriched by measurement, energy management and network analysis functions 
Earth leakage protection built into electronic protection 
Wide range of common auxiliaries and accessories interchangeable on site Compliance with international standards IEC 60947-1 and 2, IEC 68230