Second
Characteristic
Numeral
|
DEGREE OF PROTECTION (Second Number in Code)
|
|
Brief Description
|
Definition
|
|
0
|
Not
Protected |
-
|
|
1
|
Protected against vertically falling water drops. |
Vertically falling drops shall have no harmful effects. |
|
2
|
Protected against vertically falling water drops when enclosure
is titled up to 15°. |
Vertically falling drops have no harmful effects when the enclosure
is tilted at any angle up to 15° on either side of the vertical. |
|
3
|
Protected against spraying water. |
Water
sprayed at an angle up to 60° degrees on either side of the vertical
shall have no harmful effects. |
|
4
|
Protected against splashing water. |
Water
splashed against the enclosure from any direction shall have no
harmful effects. |
|
5
|
Protected against water jets. |
Water
projected in jets against the enclosure from any direction shall
have no harmful effects. |
|
6
|
Protected against powerful water jets. |
Water
projected in powerful jets against the enclosure from any direction
shall have no harmful effects. |
|
7
|
Protected against the effects of temporary immersion in water. |
Ingress of water in quantities causing harmful effects shall
not be possible when the enclosure is temporarily immersed 1 meter
in water under standardized conditions of pressure and time. |
|
8
|
Protected against the effects of continuous immersion in water. |
Ingress of water in quantities causing harmful effects shall
not be possible when the enclosure is continuously immersed in
water under conditions which shall be agreed between manufacturer
and the user, but are more severe than for number 7 |